Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Military Medical Sciences ; (12): 571-576, 2015.
Article in Chinese | WPRIM | ID: wpr-476656

ABSTRACT

Objective To establish an auto-control system for high-throughput and multi-channel DNA synthesis which can simultaneously and quickly synthesize up to 96 different oligonucleotides in a 96-well microtiter format.Methods The PLC and its extended modules is used as the main-control unit, which executes the DNA automatic synthesis process according to the synthesis sequences and steps set by the user,and the manual injecting reagent etc.And the configuration software and VC6.0 were used for programming the man-machine interface sofeware to set synthesis parameters, position calibration,flux calibration data etc, and communicated with PLC.Results The synthesis application of about 150 000 DNA chains has proved that the synthesis cycle time for 96 couplings was 4 min,the average coupling efficiency was 99%across the entire 96-well plate,the monomer reagent usage was reduced by 50 percent,and the synthesis configuration was more flexible.Conclusion A reliable and simple auto-control system is provided for parallel synthesis of 96-channel oligonucleotide chains,which can meet the demands of high-throughput and multi-channel DNA synthesis.

2.
Chinese Journal of Trauma ; (12): 211-216, 2014.
Article in Chinese | WPRIM | ID: wpr-444817

ABSTRACT

Objective To investigate the effect of prosthetic replacement for senior patients with unstable intertrochanteric fractures of the femur.Methods Fifty-three senior patients with comminuted intertrochanteric fracture of the femur were subjected to total hip arthroplasty (n =23) and bipolar artificial femoral head replacement (n =30).Uncemented long-stem prostheses were used in 50 patients and cemented long-stem prostheses in 3.Time interval between admission and surgery was 3-13 days (mean 6 days).Results The total hip arthroplasty had the operation time for mean 90 minutes (range,80-110 minutes) and blood loss for mean 350 ml (range,260-410 ml).While the hemiarthroplasty had operation time for mean 65 minutes (range,50-90 minutes) and blood loss for mean 230 ml (range,180-290 ml).Fifty-one patients were available to mean 49.6-month follow-up (range,13-65 months).Four patients presented with frequent hip pain at a tolerable level after hemiarthroplasty and the symptom was relieved after oral non-steroidal anti-inflammatory drug therapy.One patient with postoperative infection was cured by timely debridement.Seven patients were died of heart and brain disorders in 5 years,with no relation to surgical complications.The period for fracture healing was mean 10 months,with excellence rate of 96% for hip function but with no acetabulum abrasion,implant loosening or submersion.Conclusion Early prosthetic replacement is an effective treatment for unstable intertrochanteric femoral fractures in the elderly.

3.
Chinese Journal of Tissue Engineering Research ; (53): 8981-8986, 2013.
Article in Chinese | WPRIM | ID: wpr-439737

ABSTRACT

BACKGROUND:Numerous studies have shown that air wave pressure therapy plays an important role in prevention of deep venous thrombosis of lower limb after a major operation on the hip. OBJECTIVE:To explore the efficacy of air wave pressure therapy on deep vein thrombosis of the lower extremity in patients with total knee arthroplasty. METHODS:A total of 80 patients with total knee arthroplasty were randomly divided into experimental group and control group. Patients in the control group were treated only with conventional method to help the patient massage the lower extremity by the nurse and combined with active functional exercise;patients in the experimental group were treated with air wave pressure therapy at 2 days postoperatively, and were also treated with conventional method to help the patient massage the lower extremity by the nurse and combined with active functional exercise. Swel ing index, coagulation index and the number of patients with deep venous thrombosis of the lower extremity were recorded in both groups. RESULTS AND CONCLUSION:At 2 weeks after treatment, swel ing index, coagulation index and the number of patients with deep venous thrombosis of the lower extremity were significantly reduced in the experimental group, and its effects were significantly better than those in the control group (P<0.05). Early use of air wave pressure therapy after total knee arthroplasty can al eviate limb swel ing effectively and have obvious advantages in improving coagulation index and blood coagulation condition and in preventing deep vein thrombosis of the lower extremity after total knee arthroplasty.

4.
Chinese Journal of Trauma ; (12): 430-432, 2009.
Article in Chinese | WPRIM | ID: wpr-394724

ABSTRACT

Objective To investigate clinical effect of surgical repair and reconstruction of traumatic floating shoulder injuries (FSI). Methods Sixteen patients with FSI were treated with open re-duction and reconstructive internal plate fixation. Of all, one patient was with transverse clavicle fracture, six with oblique clavicle fracture and nine with comminuted clavicle fracture. There was one patient with type Ⅰ scapula fracture, three with type Ⅱ, four with type Ⅲ, six with type Ⅳ and two with type Ⅴ. The combined injuries included rib fracture plus hemopneumothorax in six patients, traumatic moist lung in two, craniocerebral injuries in two, hepatic and splenic rupture in two and brachial plexus damage in one. The average time from primary injury to operation was seven days (3-21 days). Results Fifteen out of 16 patients were followed up for 6-28 months (average 11 months). All patients obtained bone u-nion, without infection, loosening or breakage of internal fixation. According to Herscvici evaluation standard of function, the shoulder joint outcome was rated as excellent in 11 patients, good in three and fair in one, with excellence rate of 93%. Conclusion The surgical repair and reconstruction of FSI can, to a greatest extent, recover the anatomical structure and stability around the shoulder joint and shorten the immobilization period of joint, which is beneficial to functional restoration of the joint and de-crease of occurrence of complications.

5.
Journal of Third Military Medical University ; (24)2003.
Article in Chinese | WPRIM | ID: wpr-565674

ABSTRACT

Objective To evaluate the clinical efficacy of vertebroplasty using vertebral pedicle screw technique combined with calcium sulfate cement injection in the treatment of thoracolumbar vertebrae fractures.Methods Twenty-eight patients with thoracolumbar vertebrae fractures admitted in our department in recent 2 years were enrolled in this study,including 21 cases of type A,3 cases of type B,and 4 cases of type C.All patients were fixed with vertebral pedicle screw,and then verteplasty was performed using calcium sulfate cement injection.Results All patients were followed up for an average time of 16 months.Within the follow-up,there was no complication noted,such as loosening or breakage of internal fixation,chronical lumbar back pain,and loss of effected vertebral height.Artificial bones injected into vertebrae were absorbed in about 3 months.Conclusion Vertebroplasty using vertebral pedicle screw technique combined with calcium sulfate cement injection is an effective and safe procedure for thoracolumbar vertebrae fractures,which renders it possible to bear weight early and to maintain corrected vertebral height postoperatively.

SELECTION OF CITATIONS
SEARCH DETAIL